One category axis
286 of 286 factor values mapped to one category
Sweden's national combustion emission factors for stationary fuels, road vehicles, working machinery and other transport, published every year with the greenhouse gas inventory by the Swedish Environmental Protection Agency (Naturvårdsverket).
One per year and method
1 region, sub-national included
Naturvårdsverket is the Swedish government agency responsible for the national greenhouse gas inventory. With each inventory submission to the UNFCCC it publishes "Emissionsfaktorer och värmevärden" (Emission Factors and Heating Values), a workbook on the agency's website. The edition loaded is submission 2026, updated 2026-03-02, with emission years 1990 to 2024.
The agency describes the factors as national averages for different fuel combustion activities. Every factor has one value per year from 1990, and it says the factor for the year of the actual emissions is the one to use.
The workbook covers four groups. Stationary combustion covers fuel use in industry, electricity and heat production, households and small-scale combustion such as furnaces and stoves. Road transportation factors are Swedish averages per vehicle type. Working machinery factors are averages for the machines of each sub-sector: industry, households, commercial and institutional, agriculture, forestry, and an "other" sector that includes machines at airports and in ports. Other transportation covers air travel, railways and shipping. A separate table gives the CO2 factor of each pure transport fuel.
286 of 286 factor values mapped to one category
1 region as an ISO or registry code
286 take the publisher's default region, stated rather than assumed
1 canonical unit in 1 unit families, raw unit kept
0 factor values recalculated on AR6
46 factor values already on AR6
237 factor values left on the publisher's GWP
3 factor values the same on every GWP
3 boundary codes
79 factor values state in, out or varies for each scope term
158 factor values grouped under 128 parents
Use a part on its own, or the parent when you want the whole.
79 estimated supply-chain legs (well-to-tank) the publisher does not print
79 totals over burning and supply
286 of 286 factor values rated on one quality tier
English: 100.0% of factor values
German: 100.0% of factor values
French: 100.0% of factor values
Swedish: 42.3% of factor values
4,081 source rows archived
Slugs never break
Checks we run on every load to keep the data above trustworthy. Counts are for this library; the grey figure is the same check across all libraries. Point at the i to see why a check matters.
What the statuses meanHow checks are countedWhy we checkHow checks are grouped
Values that exclude a carbon pool list the gases behind the total
Known limitation · 2,513 in this library · 50,262 in all libraries
No default value is withheld for poor quality
Known limitation · 932 in this library
Every factor is filed under the most specific category its source allows
Known limitation · 3 in this library · 1,852 in all libraries
Every source category maps to our vocabulary
Enforced when loaded
The publisher's classification is kept
Passed
Every classification level has a valid parent
Passed
Every product code comes with the codes above it
Passed
A publisher's own classification is used only by that publisher
Passed
A standard classification code has one label in every library
Passed
Every region is a known code
Enforced when loaded
No named region is filed under a broader one
Passed
Every region sits in the world hierarchy
Passed
Every unit is a known code
Enforced when loaded
One source unit maps to one unit
Passed
A unit label means the same in every library
Passed
A unit label that names no basis folds one way
Passed · 1 in all libraries
Every boundary states what it includes
Passed
Boundary scope terms are known codes
Passed
No two factors for the same activity partly overlap in scope
Passed
Separate stages of one activity are linked as parts
Passed
Every part of a factor states its boundary
Passed
Every biofuel counted with its biogenic CO2 says how much
Passed
No recycling credit is hidden inside a life-cycle total
Passed
Methane and nitrous oxide figures match the stated GWP
Passed
Every convertible value has its AR6 version
Passed
CO2e totals leave out what their basis excludes
Passed
Values that exclude a carbon pool list the gases behind the total
Known limitation · 2,513 in this library · 50,262 in all libraries
Standardised figures keep every gas the publisher lists
Passed
Every value states what its CO2e total includes
Passed
A library with no AR6 version at all has a recorded reason
Passed · 2 in all libraries
Every part links to a valid parent
Passed
No factor is an unlinked part of another factor
Passed
Every factor points to its top parent
Passed · 1 in all libraries
No fuel estimate is served where the publisher printed the supply-chain figure
Passed
No supply-chain estimate is served for a fuel we deliberately left out
Passed
Every fuel estimate is built only from data we may redistribute
Passed
No fuel supply-chain estimate is rated above what its method allows
Passed
Every fuel eligible for a supply-chain estimate is classified
Passed
Every fuel supply-chain estimate still matches the figures it was computed from
Passed
The text of each fuel supply-chain estimate matches its current figures
Passed
Quality ratings fall inside their scale
Passed
Every zero value is explained
Passed
No default value is withheld for poor quality
Known limitation · 932 in this library
No implausibly high per-kilogram value is rated reliable
Passed
Every quality level gives a recognised reason
Passed
A zero that is only a gap in the source is withheld
Passed
The library is not rated entirely on one fallback quality level
Passed
Every factor has an English name
Passed
Translations match the current source text
Passed · 310 in all libraries
Translations follow a corrected source text
Passed · 4 in all libraries
Recorded translations survive a reload
Passed · 5 in all libraries
Every served factor has a name
Passed
Factors are searched on their English name where one exists
Passed · 20 in all libraries
Every language with a main name also has a full name
Passed
Full names are built from their parts in the same language
Passed
Every text is labelled with its real language
Passed
Every description is available for display and translation
Passed
Every usage note is available for display and translation
Passed
Values traced to one source row agree with each other
Passed
No duplicate factors are served
Passed · 174 in all libraries
No factor value claims two things that cannot both be true
Passed · 3,243 in all libraries
No factor value the publisher has withdrawn is still served
Passed · 10,480 in all libraries
One activity keeps one family across its units
Passed · 9 in all libraries
An activity's grouping key names only the activity
Passed · 5 in all libraries
A Creative Commons credit names its licence
Passed
No note of ours appears in the credit or licence notice
Passed
The credit line carries no terms of use
Passed
Every impact assessment method is a recognised code
Passed
Summed totals keep their parts' classification
Passed
Every summed total has a classification when its parts do
Passed
Green-electricity zeros are not rated below market-based peers
Passed
An avoided credit is linked to the burden it belongs to
Passed
Every value is typed as specific, generic or average
Passed
The market-based value is the default
Passed
Summed totals equal their parts on every gas
Passed
Validity dates are the publisher's own, never guessed
Passed
Quality breakdowns use their scheme's axes
Passed
No battery-electric vehicle carries tailpipe emissions
Passed
The text of each estimated electricity total matches its current figures
Passed
Every estimated factor carries its description in each language
Passed · 16 in all libraries
The text of each estimated factor matches its current figures
Passed
A total built on an estimated part is marked as estimated
Passed
Every estimate is built only from data we may redistribute
Passed
No estimated factor is rated above the data it was built from
Passed
No estimate sits beside a total of unclear scope
Passed
No estimate repeats a stage the publisher's total already includes
Passed · 2 in all libraries
Every factor we complete has all of its estimated parts
Passed · 7 in all libraries
No estimate is served where the publisher printed the figure
Passed · 25 in all libraries
We only estimate for publishers whose rule allows it
Passed
Every estimated factor still matches the inputs it was computed from
Passed
No estimated total competes with a published one
Passed · 24 in all libraries
Every factor with a current value has a default
Passed
Every factor has a value, in a library that publishes values
Passed
Every tagged gas has a known GWP
Passed
Every fixed group of regions lists what it covers
Passed
Where both exist, the residual mix is shown before the green-tariff zero
Passed
Every green-electricity zero is a market-based value
Passed
Every electricity factor states its mix
Passed
The newest edition of each value is the one marked current
Passed
Every publisher has a rule on whether we estimate its missing parts
Passed
Factor descriptions describe the factor, not the whole library
Passed
Every library's licence has its rights recorded
Passed
No fossil electricity mix has a zero fuel supply chain
Passed
Every green-electricity zero is exactly zero and says why
Passed
Green-electricity zeros cover power generation only
Passed
Only a total we computed may mix GWP vintages
Passed
Spend factors state their price year and basis
Passed
One default value per factor and year
Passed
Every value has a number, a GWP version and a reference year
Passed
No factor description is too long to display in full
Passed · 28 in all libraries
The library-wide answers on what a factor covers are up to date
Passed
Every library-wide answer applies to at least one factor
Passed · 3 in all libraries
Every excused arithmetic disagreement is stated
Passed
Every reference year falls between 1960 and next year
Passed
The parts of a total are never listed twice under one label
Passed
Every residual mix has its green-tariff counterpart
Passed
Every publisher's quality rating system is read
Passed
Every factor is filed under the most specific category its source allows
Known limitation · 3 in this library · 1,852 in all libraries
Every factor has a category
Passed
Every categorised factor has a GHG Protocol scope
Passed · 30 in all libraries
Single-gas values have their AR6 version
Passed · 5 in all libraries
No factor answers a question that does not arise for it
Passed · 5 in all libraries
A supplier named in the source is linked to the factor
Passed
A part covering the same scope as its total is linked to it
Passed
A year in a factor's name matches its reference year
Passed
Our reading, where no written grant settles it, checked on 4 Oct 2026
No licence on the workbook. The site's structure page: "Öppna data får användas fritt men ange gärna Naturvårdsverket som källa" (open data may be used freely, citing the agency); the 2017 re-use policy (NV-03833-13) says agency-financed data shall be CC0, but the workbook is not in the open-data catalogue. Served on the owner's risk decision of 2026-10-04 (loaded 2026-10-01, withheld until then); whether the CC0 rule covers the workbook stays asked in writing, as a confirmation, not a gate.
Credit line
Source: Naturvårdsverket, Emissionsfaktorer och värmevärden, submission 2026 (2026-03-02). Normalised by open-climate.ai, https://open-climate.ai/factors/libraries/naturvardsverket/ (CC BY 4.0)
Not legal advice: the publisher's terms prevail.
What the library covers, by category and by boundary. Click a slice to drill in, then a sub-category or a boundary to filter the factors below.
Click a slice to see what is under it. A name opens its category page; its swatch hides it from the ring.
Click a slice to see what is under it. Click a name to hide it from the ring.
top 0 matches
| Saved | Unfold | Factor | Region | Boundary | Unit |
|---|---|---|---|---|---|
| Version | Published | Loaded | Status | Source |
|---|---|---|---|---|
| 2026-03-02inventory_combustion | 2 Mar 2026 | 4 Oct 2026 | Served | Source |
Data year: the emission year printed on each gas row (1990-2024), never the 2026 submission year or the update stamp.
The workbook prints combustion only. Beside each fossil fuel factor, open-climate.ai adds an estimated well-to-tank leg (the emissions of extracting, processing and transporting the fuel) and a well-to-use total, each as its own factor marked as an estimate. The leg is the published combustion factor times the ratio of well-to-tank to combustion emissions for the same fuel. Natural gas, LNG and coking coal take the EU average of the JEC Well-to-Tank report (version 5, for 2020); the other fossil fuels take the ratio from the UK Government's 2026 greenhouse gas conversion factors. Road diesel and petrol are blends whose biofuel share changes every year, and the agency's own numbers give that share: the blend's fossil CO2 against the CO2 of the pure fossil fuel. In a year under 10% biofuel the leg takes the ratio of the UK's average blend. In a year above it (diesel from 2014, buses from 2011, petrol in 2023) the leg adds the mineral fuel's supply chain for the fossil part and the biofuel's own for the bio part, HVO for diesel and bioethanol for petrol. The 2022 passenger car diesel leg is 0.0612 kg CO2e per kWh; the blend ratio on its fossil-only value would have given 0.0409. Every leg is rated very low quality and keeps the workbook's terms. Road gas and LNG, mostly biogas, and E85 get no leg: above 10% biofuel, the combustion value leaves out too much biogenic CO2 for a multiple of it to mean anything. Nor do biofuels, waste, by-product gases such as blast furnace and coke oven gas, and fuels for which no source prints both a combustion and a well-to-tank figure, such as coke, peat and gas works gas. The agency's own numbers are unchanged: leave out estimated factors (is_estimated) to keep them only. How the fuel legs are estimated.
Open, with a reservation. The workbook carries no licence. The agency's website says "Öppna data får användas fritt men ange gärna Naturvårdsverket som källa" (open data may be used freely, but please name Naturvårdsverket as the source), and its 2017 re-use policy (NV-03833-13) says data it finances shall be licensed CC0. The workbook is not in the agency's open data catalogue, though, and neither page calls it open data. We serve the values as open, with the attribution "Source: Naturvårdsverket, Emissionsfaktorer och värmevärden, submission 2026 (2026-03-02)". Last verified 2026-10-04.
The agency has not confirmed that the CC0 rule covers the workbook. Before redistributing the values in a product of your own, confirm the terms with Naturvårdsverket.
Credit line: Source: Naturvårdsverket, Emissionsfaktorer och värmevärden, submission 2026 (2026-03-02)
A selection of Naturvårdsverket factors, with each value, boundary, source and derivation.
If Naturvårdsverket has published an edition we do not serve yet, tell us where to find it.