UPME - Unidad de Planeación Minero Energética

Colombia's CO2 combustion factors for 55 national fuels, measured on Colombian samples (FECOC 2016), and the official emission factors of the national grid (SIN) for 2019 to 2024, from the Unidad de Planeación Minero Energética (UPME).

Government
  • Electricity
  • Grid mix
SpecialistOpen licence
Factors
7
Values
42

One per year and method

Countries
1

1 region, sub-national included

Edition
sin-2024

published 23 Feb 2026 · all versions

Last loaded
3 Nov 2026

Report a newer version

Overview

UPME is the planning unit of Colombia's Ministry of Mines and Energy. It publishes two sets of factors, loaded here as two streams of one library.

  • FECOC 2016 (Factores de Emisión de los Combustibles Colombianos) is a study UPME commissioned to measure the composition of the fuels burned in Colombia: coals from ten mining basins, natural gases from each field and pipeline node, refinery products, LPG and solid biomass. Its final report is dated 9 November 2017, and the figures also feed UPME's online emissions calculator. The edition loaded is the 2016 study, the only one published.
  • The SIN emission factor is fixed each year by a UPME resolution: three combined margins under the Clean Development Mechanism method, and one factor for greenhouse gas inventories. The edition loaded runs to the act of 23 February 2026 (data year 2024).

At a glance

Publisher
Unidad de Planeación Minero Energética
Kind
Government
Scope
Specialist2 categories each hold at least 5% of its factors; the largest, Fuels, holds 91.0%. A generalist needs 4.
Home region
Colombia
Edition
sin-2024
Licence
Open licence (co-actos-administrativos)

Standardised file

Unidad de Planeación Minero Energética, standardised by open-climate.ai

The publisher's file, re-cut into the schema every library on open-climate.ai shares: one category axis, coded regions, canonical units, AR6 warming potentials, the source row kept beside each value. What is in the file

  • Edition fecoc-2016
    de7 rows · built 2026-11-17 · 89d1ae3930aaLicence requiredOpen data+
  • Edition fecoc-2016
    en7 rows · built 2026-11-17 · a07f8fe7c4d5free account required
  • Edition fecoc-2016
    en7 rows · built 2026-11-17 · d5ecdbc2518cLicence requiredOpen data+
  • Edition fecoc-2016
    fr7 rows · built 2026-11-17 · 486976757baaLicence requiredOpen data+
  • Edition sin-2024
    de7 rows · built 2026-11-17 · 0ad167766582Licence requiredOpen data+
  • Edition sin-2024
    en7 rows · built 2026-11-17 · 85e3c00b5cc8free account required
  • Edition sin-2024
    en7 rows · built 2026-11-17 · a2e4d9f58897Licence requiredOpen data+
  • Edition sin-2024
    fr7 rows · built 2026-11-17 · 852342802090Licence requiredOpen data+

What open-climate.ai standardised

over the publisher's own fileHow we standardise
9 more things standardised

Parts and parents

130 factor values grouped under 78 parents

Use a part on its own, or the parent when you want the whole.

Estimated fuel legs

65 estimated supply-chain legs (well-to-tank) the publisher does not print

65 totals over burning and supply

Languages

English: 100.0% of factor values

German: 100.0% of factor values

Spanish: 100.0% of factor values

French: 100.0% of factor values

Italian: 2.9% of factor values

Norwegian Bokmål: 2.9% of factor values

Thai: 2.9% of factor values

Audit checks

145 passed1 known limitation3 enforced when loadedlast run 17 Nov 2026

Checks we run on every load to keep the data above trustworthy. Counts are for this library; the grey figure is the same check across all libraries. Point at the i to see why a check matters.

What the statuses meanHow checks are countedWhy we checkHow checks are grouped

Needs attention

  • Where a library breaks its totals down by gas, every total is broken down or reviewed

    Known limitation · 24 in this library · 693 in all libraries

One category axis

Learn more
  • Every source category maps to our vocabulary

    Enforced when loaded

  • The publisher's classification is kept

    Passed

  • Every classification level has a valid parent

    Passed

  • Every product code comes with the codes above it

    Passed

  • A publisher's own classification is used only by that publisher

    Passed

  • A standard classification code has one label in every library

    Passed

Coded regions

Learn more
  • Every region is a known code

    Enforced when loaded

  • No named region is filed under a broader one

    Passed

  • Every region sits in the world hierarchy

    Passed

Canonical units

Learn more
  • Every unit is a known code

    Enforced when loaded

  • One source unit maps to one unit

    Passed

  • A unit label means the same in every library

    Passed

  • A unit label that names no basis folds one way

    Passed · 2 in all libraries

Declared boundaries

Learn more
  • Every boundary states what it includes

    Passed

  • Boundary scope terms are known codes

    Passed

  • No two factors for the same activity partly overlap in scope

    Passed

  • Separate stages of one activity are linked as parts, or documented as having no total

    Passed

  • Every part of a factor states its boundary

    Passed

  • Every biofuel counted with its biogenic CO2 says how much

    Passed

  • No recycling credit is hidden inside a life-cycle total

    Passed

  • No burden value hides a sizeable credit inside it

    Passed · 13 in all libraries

Warming potentials

Learn more
  • Methane and nitrous oxide figures match the stated GWP

    Passed

  • Every convertible value has its AR6 version

    Passed

  • CO2e totals leave out what their basis excludes

    Passed

  • Where a library breaks its totals down by gas, every total is broken down or reviewed

    Known limitation · 24 in this library · 693 in all libraries

  • Standardised figures keep every gas the publisher lists

    Passed

  • Every value states what its CO2e total includes

    Passed

  • A library with no AR6 version at all has a recorded reason

    Passed

Parts and parents

Learn more
  • Every part links to a valid parent

    Passed

  • No factor is an unlinked part of another factor

    Passed

  • No part is larger than the total it belongs to

    Passed

  • Every factor points to its top parent

    Passed

Estimated electricity legs

Learn more
  • No estimate is served where the publisher printed the figure

    Passed

  • Every estimate is built only from data we may redistribute

    Passed

  • No estimated factor is rated above the data it was built from

    Passed

  • Every estimated factor still matches the inputs it was computed from

    Passed

  • A total built on an estimated part is marked as estimated

    Passed

  • Every estimated factor carries its description in each language

    Passed

  • The text of each estimated factor matches its current figures

    Passed

  • The text of each estimated electricity total matches its current figures

    Passed

Estimated fuel legs

Learn more
  • No fuel estimate is served where the publisher printed the supply-chain figure

    Passed

  • No supply-chain estimate is served for a fuel we deliberately left out

    Passed

  • Every fuel estimate is built only from data we may redistribute

    Passed

  • No fuel supply-chain estimate is rated above what its method allows

    Passed

  • Every fuel eligible for a supply-chain estimate is classified

    Passed

  • Every fuel supply-chain estimate still matches the figures it was computed from

    Passed

  • The text of each fuel supply-chain estimate matches its current figures

    Passed

Electricity mix

Learn more
  • Every electricity factor states its mix

    Passed

  • The market-based value is the default

    Passed

  • One default value per factor and year

    Passed

  • Every green-electricity zero is a market-based value

    Passed

  • Green-electricity zeros are not rated below market-based peers

    Passed

Data quality

Learn more
  • Quality ratings fall inside their scale

    Passed

  • Every zero value is explained

    Passed

  • No default value is withheld without a stated reason

    Passed

  • No implausibly high per-kilogram value is rated reliable

    Passed

  • Every quality level gives a recognised reason

    Passed

  • A zero that is only a gap in the source is withheld

    Passed

  • The library is not rated entirely on one fallback quality level

    Passed

Languages

Learn more
  • Every factor has an English name

    Passed

  • Translations match the current source text

    Passed · 36 in all libraries

  • Translations follow a corrected source text

    Passed · 1 in all libraries

  • Recorded translations survive a reload

    Passed

  • Every served factor has a name

    Passed

  • Each factor's name is its English name or the publisher's own, never a mix of both

    Passed · 2 in all libraries

  • Every language with a main name also has a full name

    Passed

  • Full names are built from their parts in the same language

    Passed

  • Every text is labelled with its real language

    Passed

  • Every description is available for display and translation

    Passed

  • Every usage note is available for display and translation

    Passed

Traceable to the source

Learn more
  • Values traced to one source row agree with each other

    Passed

  • No duplicate factors are served

    Passed

  • No factor value claims two things that cannot both be true

    Passed

  • No energy factor answers a question about packaging or recycling

    Passed

  • Every served value past its publisher's end date has been reviewed

    Passed · 9 in all libraries

Other checks

  • One activity keeps one family across its units

    Passed · 8 in all libraries

  • An activity's grouping key names only the activity

    Passed · 2 in all libraries

  • A Creative Commons credit names its licence

    Passed

  • No note of ours appears in the credit or licence notice

    Passed

  • The credit line carries no terms of use

    Passed

  • Every impact assessment method is a recognised code

    Passed

  • Summed totals keep their parts' classification

    Passed

  • Every summed total has a classification when its parts do

    Passed

  • An avoided credit is linked to the burden it belongs to

    Passed

  • Every value is typed as specific, generic or average

    Passed

  • Summed totals equal their parts on every gas

    Passed

  • No total is served when one of its parts is withheld

    Passed

  • Validity dates are the publisher's own, never guessed

    Passed

  • Every district-heat factor says whether the network's heat loss is included

    Passed · 2 in all libraries

  • Quality breakdowns use their scheme's axes

    Passed

  • No battery-electric vehicle carries tailpipe emissions

    Passed

  • No EPD value is wildly off its peers without a review

    Passed

  • Every estimated district-heat leg still adds up from its sources

    Passed

  • No estimate sits beside a total of unclear scope

    Passed

  • No estimate repeats a stage the publisher's total already includes

    Passed

  • Every factor we complete has all of its estimated parts

    Passed · 247 in all libraries

  • We only estimate for publishers whose rule allows it

    Passed

  • No estimated total competes with a published one

    Passed

  • Every factor with a current value has a default

    Passed

  • Every factor has a value, in a library that publishes values

    Passed

  • Only food, farming and land factors carry a FLAG split

    Passed

  • Every FLAG land-use change figure states its method and time frame

    Passed

  • Every total equals the sum of its SBTi FLAG split

    Passed

  • Every FLAG split says whether it was published or derived

    Passed

  • Fossil-only CO2 is filed as fossil

    Passed

  • Per-gas values are in CO2e

    Passed

  • Every tagged gas has a known GWP

    Passed

  • Every fixed group of regions lists what it covers

    Passed

  • Where both exist, the residual mix is shown before the green-tariff zero

    Passed

  • The newest edition of each value is the one marked current

    Passed

  • Every publisher has a rule on whether we estimate its missing parts

    Passed

  • Factor descriptions describe the factor, not the whole library

    Passed

  • Every library's licence has its rights recorded

    Passed

  • No fossil electricity mix has a zero fuel supply chain

    Passed

  • Every green-electricity zero is exactly zero and says why

    Passed

  • Green-electricity zeros cover power generation only

    Passed

  • Only a total we computed may mix GWP vintages

    Passed

  • Spend factors state their price year and basis

    Passed

  • No electricity or heat factor answers network losses against its stage

    Passed

  • Every value has a number, a GWP version and a reference year

    Passed

  • Only a library cleared for it lists factors without their number

    Passed

  • Plug-in hybrid factors say when the electricity is left out

    Passed

  • A published total missing its fuel supply chain comes with a complete sum

    Passed

  • Product footprints headline fossil carbon, like EPDs

    Passed

  • No factor description is too long to display in full

    Passed · 11 in all libraries

  • The library-wide answers on what a factor covers are up to date

    Passed

  • Every library-wide answer applies to at least one factor

    Passed

  • Every excused arithmetic disagreement still matches the published figures

    Passed

  • Every reference year falls between 1960 and next year

    Passed

  • Each library's current edition is the one its values come from

    Passed

  • No two editions of a library share a release date

    Passed

  • The parts of a total are never listed twice under one label

    Passed

  • Every residual mix has its green-tariff counterpart

    Passed

  • Every conservative value carries the same label

    Passed

  • Every publisher's quality rating system is read

    Passed

  • Every factor's boundary includes what its category measures

    Passed

  • Every factor uses the most precise boundary for its category

    Passed

  • Every factor is filed under the most specific category its source allows

    Passed · 7,103 in all libraries

  • Every factor has a category

    Passed

  • Every categorised factor has a GHG Protocol scope

    Passed · 39 in all libraries

  • Single-gas values have their AR6 version

    Passed · 10 in all libraries

  • No factor answers a question that does not arise for it

    Passed · 9 in all libraries

  • A supplier named in the source is linked to the factor

    Passed

  • A part covering the same scope as its total is linked to it

    Passed

  • Every device total that includes its use also gives the manufacturing share (embodied emissions)

    Passed · 115 in all libraries

  • Every estimated vehicle fuel-supply leg matches its sources

    Passed

  • No plug-in vehicle supply-chain estimate is rated above what its method allows

    Passed

  • Every exhaust-only vehicle factor gets a fuel-supply leg or a recorded reason

    Passed

  • A year in a factor's name matches its reference year

    Passed

How the audit works

What can I do with this data?

Open licence · Restricted licence · credit the publisher

sin

Open licence · co-actos-administrativos
Use it to calculate my own footprint
Yes
Publish my footprint results
Yes
Share the file with my customers
Yes, if
  • you credit the publisher
Put the factors in a product I sell
Yes, if
  • you credit the publisher
Modify it or combine it with my own data
Yes, if
  • you credit the publisher

Statute, checked on 3 Nov 2026

Ley 23 de 1982 (Colombia's copyright law) Art. 41: anyone may reproduce the Constitution, laws, decrees, regulations, other administrative acts and judicial decisions, provided the reproduction conforms to the official edition. Applied to UPME's resolutions on the SIN emission factor (upme, stream sin); the conformity duty is kept as attribution to the act.

Credit line

Unidad de Planeación Minero Energética (UPME), Resoluciones del factor de emisión del SIN. Normalised by open-climate.ai, https://open-climate.ai/factors/libraries/upme/ (CC BY 4.0)

Not legal advice: the publisher's terms prevail.

Full terms

fecoc

Restricted licence · upme-terminos-condiciones
Use it to calculate my own footprint
Yes
Publish my footprint results
Yes, if
  • you credit the publisher
Modify it or combine it with my own data
Ask Unidad de Planeación Minero Energética (UPME)

Our reading, where no written grant settles it, checked on 3 Nov 2026

upme.gov.co Términos y condiciones §3.1: the site and its content are UPME's property, total or partial reproduction needs its prior written authorisation, and material may be downloaded for non-commercial use with express mention of UPME's ownership. No data licence is attached to the FECOC 2016 informe or its calculator. Owner rules 2026-11-03: load at restricted, no licence email.

Credit line

Unidad de Planeación Minero Energética (UPME), Factores de Emisión de los Combustibles Colombianos FECOC 2016. Normalised by open-climate.ai, https://open-climate.ai/factors/libraries/upme/ (CC BY 4.0)

Not legal advice: the publisher's terms prevail.

Full terms

How to read these answers

Coverage

What the library covers, by category and by boundary. Click a slice to drill in, then a sub-category or a boundary to filter the factors below.

By category

Fuels: 71Electricity: 7
78factors

Click a slice to see what is under it. A name opens its category page; its swatch hides it from the ring.

By boundary

Energy, full chain: 65Direct only: 10Supply chain only: 3
78factors

Click a slice to see what is under it. Click a name to hide it from the ring.

Browse factors

top 0 matches

SavedUnfoldFactorRegionBoundary
Unit
VersionPublishedLoadedStatusSource
sin-2024sin23 Feb 20263 Nov 2026ServedSource

Methodology

How this works
  • FECOC computes each fuel's CO2 from its measured carbon content and net calorific value, assuming full oxidation. The figure is the CO2 of burning the fuel, nothing upstream. It is printed per terajoule on the net calorific value, and per one physical unit of the fuel: dry tonne for coals and solid biomass, gallon for liquids, kilogram for LPG and standard cubic metre (60 °F, 101.325 kPa) for gases.
  • Only CO2 is computed. FECOC's methane and nitrous oxide figures are the IPCC default values reprinted, so we do not load them; the CO2e we serve for FECOC is the CO2 alone.
  • The CO2 of biomass, which FECOC prints, is counted as carbon neutral by the report. We keep the fossil CO2 at zero for those fuels and do not serve a zero as a footprint: their values are withheld.
  • The SIN inventory factor is the emissions intensity of Colombia's grid generation over one year, which the act says serves to estimate the indirect emissions of electricity consumption. It counts CO2, CH4 and N2O; the act names no GWP set. It does not include transmission and distribution losses.
  • The three SIN combined margins (I for wind and solar projects, II and III for other projects in their first and later crediting periods) are the generation a new project displaces. They are for emission reduction projects, not for a consumer's footprint, and are filed as electricity generation.
  • Values are served per kWh of fuel or electricity, converted from kg per TJ and from tonnes per MWh.
  • The reference year is 2016 for FECOC (the study year; samples were taken in 2015 and 2016) and, for SIN, the data year each act names.

What we import

  • 105 factors and 125 values, all for Colombia.
  • FECOC: 101 factors for 55 fuels: 11 coals (a national generic and ten basins), 14 liquid fuels (among them diesel, motor petrol, jet fuel, kerosene, fuel oil, a heavy crude and four LPGs), 13 gaseous fuels (natural gas by field and pipeline node, coke oven gas), 16 biomass fuels and tyre-derived fuel. Each fuel has a factor per terajoule and, for most, one per physical unit.
  • SIN: 4 factors and 24 values, one per data year from 2019 to 2024: the inventory factor and the three combined margins.
  • Factor names are UPME's own Spanish labels. The composition, calorific values, density and flue gas concentration behind each fuel are kept with its source record.
  • Factors are placed in the open-climate.ai category tree: grid electricity and electricity generation, and under fuels solid fossil, liquid fossil, gaseous fossil, biofuel and waste-derived fuel.
  • Not loaded: the 118 methane and nitrous oxide rows (IPCC defaults), 9 FECOC cells whose carbon content is implausible (Avigas, palm biodiesel, marine diesel and E10 petrol), 3 blends that exist only in the calculator, 10 calculator grid constants with no act behind them, 5 calculator duplicates of an act, and the 4 values of Resolution 762 of 2023, replaced by Resolution 705 of 2024.

FECOC covers combustion only. Beside 65 factors of 33 fossil fuels, open-climate.ai adds an estimated well-to-tank leg (the emissions of extracting, processing and transporting the fuel) and a well-to-use total, each as its own factor marked as an estimate. UPME publishes no well-to-tank figure, so the leg is the published combustion factor times the ratio of well-to-tank to combustion emissions for the matching fuel in the UK Government's greenhouse gas conversion factors. Every fuel leg is rated very low quality. Coke oven gas (a by-product), Crudo de Castilla (no comparable fuel prints both figures), tyre-derived fuel (waste-derived) and the biomass fuels (biogenic) get none. The SIN inventory factor gets three estimated legs: transmission and distribution losses, the upstream of those losses, and the fuel supply chain of the power plants. It gets no well-to-use total: the acts name no GWP set, and we do not add legs on a named set to a figure on an unnamed one. The combined margins get no leg. The legs and totals carry the same terms as the factor they extend. UPME's own numbers are unchanged: leave out estimated factors (is_estimated) to keep them only. How the fuel legs are estimated.

Two terms, one per stream.

  • FECOC: restricted. The report and the calculator carry no data licence. UPME's site terms state that the site and its content are UPME's property, that total or partial reproduction needs its prior written authorisation, and that material may be downloaded for non-commercial use with express mention of UPME's ownership. Using the factors for your own footprint is allowed, and publishing results is allowed with UPME named as the source. Sharing the values with customers and embedding them in a product are not granted, so we record them as unclear, and modifying or combining the values needs UPME's permission. Until UPME grants reuse in writing, the FECOC factors are listed and searchable with their descriptions, and their values are not shown on the public site; the estimated legs and totals are restricted with them.
  • SIN: open. The factors are fixed by resolutions, which are administrative acts. Article 41 of Colombia's copyright law (Ley 23 de 1982) lets anyone reproduce administrative acts, provided the reproduction conforms to the official edition. We keep that duty as attribution to the act.

Attribution: "Unidad de Planeación Minero Energética (UPME), Factores de Emisión de los Combustibles Colombianos FECOC 2016" for FECOC, and "Unidad de Planeación Minero Energética (UPME), Resoluciones del factor de emisión del SIN" for the grid factors. Last verified 2026-11-03.

What can I do with this data?

Credit line: Unidad de Planeación Minero Energética (UPME), Resoluciones del factor de emisión del SIN

co-actos-administrativos

Es permitido a todos reproducir la Constitución, leyes, decretos, ordenanzas, acuerdos, reglamentos, demás actos administrativos y decisiones judiciales, bajo la obligación de conformarse puntualmente con la edición oficial, siempre y cuando no esté prohibido.

Limitations

  • FECOC is CO2 only and combustion only: methane, nitrous oxide and every upstream emission are left out, so the factors understate a full greenhouse gas footprint.
  • FECOC is a 2016 study, never updated. Fuel quality, biofuel blends and gas field mixes have changed since.
  • The SIN factors are location-based national averages: they do not reflect green power purchases or a supplier's own mix, and they leave out network losses and the fuel supply chain of the power plants.
  • A later resolution can replace the figures of an earlier one for the same data year: Resolution 705 of 2024 replaced the 2022 figures of Resolution 762 of 2023 (combined margin III from 0.154 to 0.289 t per MWh, II from 0.165 to 0.391, I from 0.176 to 0.493). We serve the replacing act only.
  • The combined margins are not consumption factors. Use the inventory factor for the electricity you consume.
  • FECOC's 71 served values and the 24 SIN values are rated medium quality: national averages, not measured at your plant or on your supply. The estimated fuel legs are rated very low and the electricity legs low. The well-to-use totals are rated medium, except those of the 11 coals per kWh and per dry tonne, rated very low.
  • How quality tiers are set.

Changelog

  • 2026-11-03: FECOC 2016 loaded, restricted, and the SIN factors for data years 2019 to 2024, open.

Know a newer edition?

If UPME has published an edition we do not serve yet, tell us where to find it.