Kiwa-EE - Kiwa-Ecobility Experts EPD programme (Kiwa GmbH)

The register of verified Environmental Product Declarations of Kiwa-Ecobility Experts, a German programme operator: the climate impact of construction products, per life cycle module.

Commercial
  • EPD
  • Construction
SpecialistOpen licence
Factors
4,174
Values
4,179

One per year and method

Countries
25

28 regions, sub-national included

Edition
KIWA_EE_2026-10-02

published 2 Oct 2026 · all versions

Last loaded
17 Nov 2026

Report a newer version

Overview

Kiwa-Ecobility Experts is the EPD programme of Kiwa GmbH in Germany. Manufacturers from Germany and the rest of Europe publish third-party verified EPDs under its rules: insulation, mortars and plasters, concrete products, windows and doors, membranes, timber and building services. The programme's site is kiwa.com.

Its digital datasets are published in the ILCD+EPD format on the soda4LCA node kiwa.lca-data.com, the same format and interface ÖKOBAUDAT uses.

At a glance

Publisher
Kiwa-Ecobility Experts EPD programme (Kiwa GmbH)
Kind
Commercial
Scope
Specialist2 categories each hold at least 5% of its factors; the largest, Materials, holds 84.1%. A generalist needs 4.
Home region
Germany
Edition
KIWA_EE_2026-10-02
Licence
Open licence (kiwa-ee-terms)

Standardised file

Kiwa-Ecobility Experts EPD programme (Kiwa GmbH), standardised by open-climate.ai

The publisher's file, re-cut into the schema every library on open-climate.ai shares: one category axis, coded regions, canonical units, AR6 warming potentials, the source row kept beside each value. What is in the file

  • Edition KIWA_EE_2026-10-02
    de4,391 rows · built 2026-10-06 · e7698488aaaaLicence requiredOpen data+
  • Edition KIWA_EE_2026-10-02
    en4,391 rows · built 2026-10-06 · c4190a0e16c9free account required
  • Edition KIWA_EE_2026-10-02
    en4,391 rows · built 2026-10-06 · e044a7cd8858Licence requiredOpen data+
  • Edition KIWA_EE_2026-10-02
    fr4,391 rows · built 2026-10-06 · 13b368352c29Licence requiredOpen data+

What open-climate.ai standardised

over the publisher's own fileHow we standardise

Warming potentials

0 factor values recalculated on AR6

1,121 factor values already on AR6

3,053 factor values left on the publisher's GWP

8 more things standardised

Parts and parents

3,811 factor values grouped under 363 parents

Use a part on its own, or the parent when you want the whole.

Audit checks

144 passed2 known limitations3 enforced when loadedlast run 17 Nov 2026

Checks we run on every load to keep the data above trustworthy. Counts are for this library; the grey figure is the same check across all libraries. Point at the i to see why a check matters.

What the statuses meanHow checks are countedWhy we checkHow checks are grouped

Needs attention

  • No burden value hides a sizeable credit inside it

    Known limitation · 1 in this library · 13 in all libraries

  • No factor description is too long to display in full

    Known limitation · 3 in this library · 11 in all libraries

One category axis

Learn more
  • Every source category maps to our vocabulary

    Enforced when loaded

  • The publisher's classification is kept

    Passed

  • Every classification level has a valid parent

    Passed

  • Every product code comes with the codes above it

    Passed

  • A publisher's own classification is used only by that publisher

    Passed

  • A standard classification code has one label in every library

    Passed

Coded regions

Learn more
  • Every region is a known code

    Enforced when loaded

  • No named region is filed under a broader one

    Passed

  • Every region sits in the world hierarchy

    Passed

Canonical units

Learn more
  • Every unit is a known code

    Enforced when loaded

  • One source unit maps to one unit

    Passed

  • A unit label means the same in every library

    Passed

  • A unit label that names no basis folds one way

    Passed · 2 in all libraries

Declared boundaries

Learn more
  • Every boundary states what it includes

    Passed

  • Boundary scope terms are known codes

    Passed

  • No two factors for the same activity partly overlap in scope

    Passed

  • Separate stages of one activity are linked as parts, or documented as having no total

    Passed

  • Every part of a factor states its boundary

    Passed

  • Every biofuel counted with its biogenic CO2 says how much

    Passed

  • No recycling credit is hidden inside a life-cycle total

    Passed

  • No burden value hides a sizeable credit inside it

    Known limitation · 1 in this library · 13 in all libraries

Warming potentials

Learn more
  • Methane and nitrous oxide figures match the stated GWP

    Passed

  • Every convertible value has its AR6 version

    Passed

  • CO2e totals leave out what their basis excludes

    Passed

  • Where a library breaks its totals down by gas, every total is broken down or reviewed

    Passed · 693 in all libraries

  • Standardised figures keep every gas the publisher lists

    Passed

  • Every value states what its CO2e total includes

    Passed

  • A library with no AR6 version at all has a recorded reason

    Passed

Parts and parents

Learn more
  • Every part links to a valid parent

    Passed

  • No factor is an unlinked part of another factor

    Passed

  • No part is larger than the total it belongs to

    Passed

  • Every factor points to its top parent

    Passed

Summed totals

Learn more
  • Summed totals equal their parts on every gas

    Passed

  • No total is served when one of its parts is withheld

    Passed

  • Every summed total has a classification when its parts do

    Passed

  • Summed totals keep their parts' classification

    Passed

Data quality

Learn more
  • Quality ratings fall inside their scale

    Passed

  • Every zero value is explained

    Passed

  • No default value is withheld without a stated reason

    Passed

  • No implausibly high per-kilogram value is rated reliable

    Passed

  • Every quality level gives a recognised reason

    Passed

  • A zero that is only a gap in the source is withheld

    Passed

  • The library is not rated entirely on one fallback quality level

    Passed

EPDs and suppliers

Learn more
  • A supplier named in the source is linked to the factor

    Passed

Languages

Learn more
  • Every factor has an English name

    Passed

  • Translations match the current source text

    Passed · 36 in all libraries

  • Translations follow a corrected source text

    Passed · 1 in all libraries

  • Recorded translations survive a reload

    Passed

  • Every served factor has a name

    Passed

  • Each factor's name is its English name or the publisher's own, never a mix of both

    Passed · 2 in all libraries

  • Every language with a main name also has a full name

    Passed

  • Full names are built from their parts in the same language

    Passed

  • Every text is labelled with its real language

    Passed

  • Every description is available for display and translation

    Passed

  • Every usage note is available for display and translation

    Passed

Traceable to the source

Learn more
  • Values traced to one source row agree with each other

    Passed

  • No duplicate factors are served

    Passed

  • No factor value claims two things that cannot both be true

    Passed

  • No energy factor answers a question about packaging or recycling

    Passed

  • Every served value past its publisher's end date has been reviewed

    Passed · 9 in all libraries

Other checks

  • One activity keeps one family across its units

    Passed · 8 in all libraries

  • An activity's grouping key names only the activity

    Passed · 2 in all libraries

  • A Creative Commons credit names its licence

    Passed

  • No note of ours appears in the credit or licence notice

    Passed

  • The credit line carries no terms of use

    Passed

  • Every impact assessment method is a recognised code

    Passed

  • Green-electricity zeros are not rated below market-based peers

    Passed

  • An avoided credit is linked to the burden it belongs to

    Passed

  • Every value is typed as specific, generic or average

    Passed

  • The market-based value is the default

    Passed

  • Validity dates are the publisher's own, never guessed

    Passed

  • Every district-heat factor says whether the network's heat loss is included

    Passed · 2 in all libraries

  • Quality breakdowns use their scheme's axes

    Passed

  • No battery-electric vehicle carries tailpipe emissions

    Passed

  • The text of each estimated electricity total matches its current figures

    Passed

  • No EPD value is wildly off its peers without a review

    Passed

  • Every estimated factor carries its description in each language

    Passed

  • The text of each estimated factor matches its current figures

    Passed

  • A total built on an estimated part is marked as estimated

    Passed

  • Every estimated district-heat leg still adds up from its sources

    Passed

  • Every estimate is built only from data we may redistribute

    Passed

  • No estimated factor is rated above the data it was built from

    Passed

  • No estimate sits beside a total of unclear scope

    Passed

  • No estimate repeats a stage the publisher's total already includes

    Passed

  • Every factor we complete has all of its estimated parts

    Passed · 247 in all libraries

  • No estimate is served where the publisher printed the figure

    Passed

  • We only estimate for publishers whose rule allows it

    Passed

  • Every estimated factor still matches the inputs it was computed from

    Passed

  • No estimated total competes with a published one

    Passed

  • Every factor with a current value has a default

    Passed

  • Every factor has a value, in a library that publishes values

    Passed

  • Only food, farming and land factors carry a FLAG split

    Passed

  • Every FLAG land-use change figure states its method and time frame

    Passed

  • Every total equals the sum of its SBTi FLAG split

    Passed

  • Every FLAG split says whether it was published or derived

    Passed

  • Fossil-only CO2 is filed as fossil

    Passed

  • The text of each fuel supply-chain estimate matches its current figures

    Passed

  • No fuel supply-chain estimate is rated above what its method allows

    Passed

  • Every fuel estimate is built only from data we may redistribute

    Passed

  • Every fuel eligible for a supply-chain estimate is classified

    Passed

  • No fuel estimate is served where the publisher printed the supply-chain figure

    Passed

  • No supply-chain estimate is served for a fuel we deliberately left out

    Passed

  • Every fuel supply-chain estimate still matches the figures it was computed from

    Passed

  • Per-gas values are in CO2e

    Passed

  • Every tagged gas has a known GWP

    Passed

  • Every fixed group of regions lists what it covers

    Passed

  • Where both exist, the residual mix is shown before the green-tariff zero

    Passed

  • Every green-electricity zero is a market-based value

    Passed

  • Every electricity factor states its mix

    Passed

  • The newest edition of each value is the one marked current

    Passed

  • Every publisher has a rule on whether we estimate its missing parts

    Passed

  • Factor descriptions describe the factor, not the whole library

    Passed

  • Every library's licence has its rights recorded

    Passed

  • No fossil electricity mix has a zero fuel supply chain

    Passed

  • Every green-electricity zero is exactly zero and says why

    Passed

  • Green-electricity zeros cover power generation only

    Passed

  • Only a total we computed may mix GWP vintages

    Passed

  • Spend factors state their price year and basis

    Passed

  • One default value per factor and year

    Passed

  • No electricity or heat factor answers network losses against its stage

    Passed

  • Every value has a number, a GWP version and a reference year

    Passed

  • Only a library cleared for it lists factors without their number

    Passed

  • Plug-in hybrid factors say when the electricity is left out

    Passed

  • A published total missing its fuel supply chain comes with a complete sum

    Passed

  • Product footprints headline fossil carbon, like EPDs

    Passed

  • No factor description is too long to display in full

    Known limitation · 3 in this library · 11 in all libraries

  • The library-wide answers on what a factor covers are up to date

    Passed

  • Every library-wide answer applies to at least one factor

    Passed

  • Every excused arithmetic disagreement still matches the published figures

    Passed

  • Every reference year falls between 1960 and next year

    Passed

  • Each library's current edition is the one its values come from

    Passed

  • No two editions of a library share a release date

    Passed

  • The parts of a total are never listed twice under one label

    Passed

  • Every residual mix has its green-tariff counterpart

    Passed

  • Every conservative value carries the same label

    Passed

  • Every publisher's quality rating system is read

    Passed

  • Every factor's boundary includes what its category measures

    Passed

  • Every factor uses the most precise boundary for its category

    Passed

  • Every factor is filed under the most specific category its source allows

    Passed · 7,103 in all libraries

  • Every factor has a category

    Passed

  • Every categorised factor has a GHG Protocol scope

    Passed · 39 in all libraries

  • Single-gas values have their AR6 version

    Passed · 10 in all libraries

  • No factor answers a question that does not arise for it

    Passed · 9 in all libraries

  • A part covering the same scope as its total is linked to it

    Passed

  • Every device total that includes its use also gives the manufacturing share (embodied emissions)

    Passed · 115 in all libraries

  • Every estimated vehicle fuel-supply leg matches its sources

    Passed

  • No plug-in vehicle supply-chain estimate is rated above what its method allows

    Passed

  • Every exhaust-only vehicle factor gets a fuel-supply leg or a recorded reason

    Passed

  • A year in a factor's name matches its reference year

    Passed

How the audit works

What can I do with this data?

Open licence · credit the publisher

Your rights

Open licence · kiwa-ee-terms
Use it to calculate my own footprint
Yes
Publish my footprint results
Yes, if
  • you credit the publisher
Share the file with my customers
Unclear: ask Kiwa GmbH, Ecobility Experts
Put the factors in a product I sell
Unclear: ask Kiwa GmbH, Ecobility Experts
Modify it or combine it with my own data
Unclear: ask Kiwa GmbH, Ecobility Experts

Written confirmation from the publisher, checked on 21 Oct 2026

Kiwa-EE, by email 2026-10-21, on serving the node's EPDs as declared and credited: "In general, this is fine". As programme operator it keeps control over where its EPDs are published and that they are up to date, so it holds the list of EPD numbers we serve and two contacts for corrections or removals.

Credit line

Kiwa-Ecobility Experts EPD programme (Kiwa GmbH), EPD data from https://kiwa.lca-data.com. Normalised by open-climate.ai, https://open-climate.ai/factors/libraries/kiwa_ee/ (CC BY 4.0)

Not legal advice: the publisher's terms prevail.

Full terms

How to read these answers

Coverage

What the library covers, by category and by boundary. Click a slice to drill in, then a sub-category or a boundary to filter the factors below.

By category

Materials: 307Manufactured goods: 58
365factors

Click a slice to see what is under it. A name opens its category page; its swatch hides it from the ring.

By boundary

Full life cycle: 350Cradle to gate: 15
365factors

Click a slice to see what is under it. Click a name to hide it from the ring.

Browse factors

top 0 matches

SavedUnfoldFactorRegionBoundary
Unit

Checked for updates 17 Nov 2026: the publisher has released something newer, which we are reviewing (1 signal watched)

VersionPublishedLoadedStatusSource
KIWA_EE_2026-10-022 Oct 202617 Nov 2026ServedSource

Methodology

How this works
  • Values are global warming potential per declared unit (per kg, m³, m², m or piece), reported per life cycle module: A1-A3 product stage, A4-A5 construction, B1-B7 use, C1-C4 end of life, and D, benefits beyond the system boundary.
  • Every dataset follows EN 15804+A2, with the EF 3.0 or EF 3.1 characterisation, and the served number is GWP-fossil, with the total, biogenic and land use parts kept beside it.
  • No breakdown by gas is published, so the values cannot be restated in AR6.
  • Each EPD gets one total over the modules it declares, built the same way as for ÖKOBAUDAT: cradle to gate for A1-A3, cradle to grave when every A to C module is declared. Where the EPD prints A1, A2 and A3 without their sum, the cradle to gate total is their sum; where it prints the sum, the parts are linked under it. Module D is shown beside the total, never added to it.
  • Where an EPD declares more than one end-of-life scenario, for example one per country, each is kept, and the one it names as standard is served by default.
  • The reference year is the dataset's own reference year, which on this node is the year of the data, usually one or two years before the EPD was published. 142 datasets state none; they are dated two years before their publication date, the node's usual gap, and the two without a publication date two years before their entry date.
  • Most datasets are product or manufacturer specific; the rest are averages over several plants, products or members of a sector association.

Mixed: the EPD's declared ILCD reference year, which is a data year on Kiwa-EE and most often the year the EPD was published on the other nodes. An EPD that states none is dated off its own publication or entry date.

What we import

  • The node as harvested on 2026-10-02: 393 of the 728 datasets it lists, one factor per module.
  • The 335 datasets that are also published in ÖKOBAUDAT are served there and not loaded twice.
  • The declaration owner is shown as the supplier.
  • Each dataset is placed in an open-climate.ai category, read from the ÖKOBAUDAT product classes most datasets carry, and otherwise from its product name.
  • Values declared per tonne or another amount are converted to the declared unit.
  • Not imported: the EN 15804 indicators other than GWP.
  • Names are as published, most in English. 31 datasets carry a German name only; they are shown in our English translation, marked as translated, with the German name kept.

Open. Kiwa-Ecobility Experts confirmed in writing on 2026-10-21 that serving its EPDs here is fine. As programme operator, it keeps control over where its EPDs are published and that they are up to date: it holds the list of EPD numbers we serve, and an EPD it asks us to correct or remove is corrected or removed right away.

From 2026-10-06 to 2026-10-27 the library was hidden, while no written grant covered serving the node's datasets publicly. Kiwa-Ecobility Experts' general programme instructions (revision 04) publish each EPD with its owner's consent (section 8.1.2), and every dataset on the node states it is free of charge for all users and uses. Attribution: "Kiwa-Ecobility Experts (Kiwa GmbH), EPD data from https://kiwa.lca-data.com". Last verified 2026-10-21.

What can I do with this data?

Credit line: Kiwa-Ecobility Experts EPD programme (Kiwa GmbH), EPD data from https://kiwa.lca-data.com

kiwa-ee-terms

Limitations

  • Some product names carry a model code that reads like a year. They are loaded as published.

Changelog

  • 2026-10-05: node harvest of 2026-10-02 loaded.
  • 2026-10-06: library hidden; none of its factors is served.
  • 2026-10-27: library served again, open, on Kiwa-Ecobility Experts' written confirmation.

Know a newer edition?

If Kiwa-EE has published an edition we do not serve yet, tell us where to find it.