KEITI LCI - 한국환경산업기술원 (KEITI), 국가 LCI 데이터베이스 / Korea National LCI Database

South Korea's national life-cycle inventory database, open set: cradle-to-gate climate totals for 280 Korean materials, chemicals, fuels, electricity mixes, freight transport and waste treatments.

Government
  • LCI
  • Electricity
  • Transport
  • Waste
GeneralistOpen licence
Factors
264
Values
264

One per year and method

Countries
1

1 region, sub-national included

Edition
node-20261109

all versions

Last loaded
16 Nov 2026

Report a newer version

Overview

The Korea Environmental Industry and Technology Institute (KEITI, 한국환경산업기술원) maintains the Korea National LCI Database, the background data behind Korean environmental product declarations. It publishes the datasets on a soda4LCA node in the ILCD format. The node serves 367 datasets to anyone; 160 more need a free registration. We harvested the open set on 9 November 2026. The node prints no edition label, so the edition is the harvest date.

This is the process-data half of KEITI's work. Korean product declarations (EPDs) are a separate library, the Korean EPD registry.

At a glance

Publisher
한국환경산업기술원 (KEITI), 국가 LCI 데이터베이스 / Korea National LCI Database
Kind
Government
Scope
Generalist6 categories each hold at least 5% of its factors; the largest, Materials, holds 50.8%. A generalist needs 4.
Home region
South Korea
Edition
node-20261109
Licence
Open licence (keiti-lci-terms)

Standardised file

한국환경산업기술원 (KEITI), 국가 LCI 데이터베이스 / Korea National LCI Database, standardised by open-climate.ai

The publisher's file, re-cut into the schema every library on open-climate.ai shares: one category axis, coded regions, canonical units, AR6 warming potentials, the source row kept beside each value. What is in the file

  • Edition node-20261109
    de264 rows · built 2026-11-17 · 1dda2c1f3187Licence requiredOpen data+
  • Edition node-20261109
    en264 rows · built 2026-11-17 · 01cb2259e649free account required
  • Edition node-20261109
    en264 rows · built 2026-11-17 · ca95e37a95c8Licence requiredOpen data+
  • Edition node-20261109
    fr264 rows · built 2026-11-17 · 18672f0c9ac2Licence requiredOpen data+

What open-climate.ai standardised

over the publisher's own fileHow we standardise

Warming potentials

0 factor values recalculated on AR6

264 factor values already on AR6

0 factor values left on the publisher's GWP

6 more things standardised

Audit checks

145 passed1 known limitation3 enforced when loadedlast run 17 Nov 2026

Checks we run on every load to keep the data above trustworthy. Counts are for this library; the grey figure is the same check across all libraries. Point at the i to see why a check matters.

What the statuses meanHow checks are countedWhy we checkHow checks are grouped

Needs attention

  • Each factor's name is its English name or the publisher's own, never a mix of both

    Known limitation · 1 in this library · 2 in all libraries

One category axis

Learn more
  • Every source category maps to our vocabulary

    Enforced when loaded

  • The publisher's classification is kept

    Passed

  • Every classification level has a valid parent

    Passed

  • Every product code comes with the codes above it

    Passed

  • A publisher's own classification is used only by that publisher

    Passed

  • A standard classification code has one label in every library

    Passed

Coded regions

Learn more
  • Every region is a known code

    Enforced when loaded

  • No named region is filed under a broader one

    Passed

  • Every region sits in the world hierarchy

    Passed

Canonical units

Learn more
  • Every unit is a known code

    Enforced when loaded

  • One source unit maps to one unit

    Passed

  • A unit label means the same in every library

    Passed

  • A unit label that names no basis folds one way

    Passed · 2 in all libraries

Declared boundaries

Learn more
  • Every boundary states what it includes

    Passed

  • Boundary scope terms are known codes

    Passed

  • No two factors for the same activity partly overlap in scope

    Passed

  • Separate stages of one activity are linked as parts, or documented as having no total

    Passed

  • Every part of a factor states its boundary

    Passed

  • Every biofuel counted with its biogenic CO2 says how much

    Passed

  • No recycling credit is hidden inside a life-cycle total

    Passed

  • No burden value hides a sizeable credit inside it

    Passed · 13 in all libraries

Warming potentials

Learn more
  • Methane and nitrous oxide figures match the stated GWP

    Passed

  • Every convertible value has its AR6 version

    Passed

  • CO2e totals leave out what their basis excludes

    Passed

  • Where a library breaks its totals down by gas, every total is broken down or reviewed

    Passed · 693 in all libraries

  • Standardised figures keep every gas the publisher lists

    Passed

  • Every value states what its CO2e total includes

    Passed

  • A library with no AR6 version at all has a recorded reason

    Passed

Electricity mix

Learn more
  • Every electricity factor states its mix

    Passed

  • The market-based value is the default

    Passed

  • One default value per factor and year

    Passed

  • Every green-electricity zero is a market-based value

    Passed

  • Green-electricity zeros are not rated below market-based peers

    Passed

Data quality

Learn more
  • Quality ratings fall inside their scale

    Passed

  • Every zero value is explained

    Passed

  • No default value is withheld without a stated reason

    Passed

  • No implausibly high per-kilogram value is rated reliable

    Passed

  • Every quality level gives a recognised reason

    Passed

  • A zero that is only a gap in the source is withheld

    Passed

  • The library is not rated entirely on one fallback quality level

    Passed

Languages

Learn more
  • Every factor has an English name

    Passed

  • Translations match the current source text

    Passed · 36 in all libraries

  • Translations follow a corrected source text

    Passed · 1 in all libraries

  • Recorded translations survive a reload

    Passed

  • Every served factor has a name

    Passed

  • Each factor's name is its English name or the publisher's own, never a mix of both

    Known limitation · 1 in this library · 2 in all libraries

  • Every language with a main name also has a full name

    Passed

  • Full names are built from their parts in the same language

    Passed

  • Every text is labelled with its real language

    Passed

  • Every description is available for display and translation

    Passed

  • Every usage note is available for display and translation

    Passed

Traceable to the source

Learn more
  • Values traced to one source row agree with each other

    Passed

  • No duplicate factors are served

    Passed

  • No factor value claims two things that cannot both be true

    Passed

  • No energy factor answers a question about packaging or recycling

    Passed

  • Every served value past its publisher's end date has been reviewed

    Passed · 9 in all libraries

Other checks

  • One activity keeps one family across its units

    Passed · 8 in all libraries

  • An activity's grouping key names only the activity

    Passed · 2 in all libraries

  • A Creative Commons credit names its licence

    Passed

  • No note of ours appears in the credit or licence notice

    Passed

  • The credit line carries no terms of use

    Passed

  • Every part links to a valid parent

    Passed

  • Every impact assessment method is a recognised code

    Passed

  • Summed totals keep their parts' classification

    Passed

  • Every summed total has a classification when its parts do

    Passed

  • An avoided credit is linked to the burden it belongs to

    Passed

  • Every value is typed as specific, generic or average

    Passed

  • Summed totals equal their parts on every gas

    Passed

  • No total is served when one of its parts is withheld

    Passed

  • Validity dates are the publisher's own, never guessed

    Passed

  • Every district-heat factor says whether the network's heat loss is included

    Passed · 2 in all libraries

  • Quality breakdowns use their scheme's axes

    Passed

  • No battery-electric vehicle carries tailpipe emissions

    Passed

  • The text of each estimated electricity total matches its current figures

    Passed

  • No EPD value is wildly off its peers without a review

    Passed

  • Every estimated factor carries its description in each language

    Passed

  • The text of each estimated factor matches its current figures

    Passed

  • A total built on an estimated part is marked as estimated

    Passed

  • Every estimated district-heat leg still adds up from its sources

    Passed

  • Every estimate is built only from data we may redistribute

    Passed

  • No estimated factor is rated above the data it was built from

    Passed

  • No estimate sits beside a total of unclear scope

    Passed

  • No estimate repeats a stage the publisher's total already includes

    Passed

  • Every factor we complete has all of its estimated parts

    Passed · 247 in all libraries

  • No estimate is served where the publisher printed the figure

    Passed

  • We only estimate for publishers whose rule allows it

    Passed

  • Every estimated factor still matches the inputs it was computed from

    Passed

  • No estimated total competes with a published one

    Passed

  • Every factor with a current value has a default

    Passed

  • Every factor has a value, in a library that publishes values

    Passed

  • Only food, farming and land factors carry a FLAG split

    Passed

  • Every FLAG land-use change figure states its method and time frame

    Passed

  • Every total equals the sum of its SBTi FLAG split

    Passed

  • Every FLAG split says whether it was published or derived

    Passed

  • Fossil-only CO2 is filed as fossil

    Passed

  • The text of each fuel supply-chain estimate matches its current figures

    Passed

  • No fuel supply-chain estimate is rated above what its method allows

    Passed

  • Every fuel estimate is built only from data we may redistribute

    Passed

  • Every fuel eligible for a supply-chain estimate is classified

    Passed

  • No fuel estimate is served where the publisher printed the supply-chain figure

    Passed

  • No supply-chain estimate is served for a fuel we deliberately left out

    Passed

  • Every fuel supply-chain estimate still matches the figures it was computed from

    Passed

  • Per-gas values are in CO2e

    Passed

  • Every tagged gas has a known GWP

    Passed

  • Every fixed group of regions lists what it covers

    Passed

  • Where both exist, the residual mix is shown before the green-tariff zero

    Passed

  • The newest edition of each value is the one marked current

    Passed

  • Every publisher has a rule on whether we estimate its missing parts

    Passed

  • Factor descriptions describe the factor, not the whole library

    Passed

  • Every library's licence has its rights recorded

    Passed

  • No fossil electricity mix has a zero fuel supply chain

    Passed

  • Every green-electricity zero is exactly zero and says why

    Passed

  • Green-electricity zeros cover power generation only

    Passed

  • Only a total we computed may mix GWP vintages

    Passed

  • Spend factors state their price year and basis

    Passed

  • No electricity or heat factor answers network losses against its stage

    Passed

  • Every value has a number, a GWP version and a reference year

    Passed

  • Only a library cleared for it lists factors without their number

    Passed

  • Plug-in hybrid factors say when the electricity is left out

    Passed

  • A published total missing its fuel supply chain comes with a complete sum

    Passed

  • Product footprints headline fossil carbon, like EPDs

    Passed

  • No factor description is too long to display in full

    Passed · 11 in all libraries

  • The library-wide answers on what a factor covers are up to date

    Passed

  • Every library-wide answer applies to at least one factor

    Passed

  • Every excused arithmetic disagreement still matches the published figures

    Passed

  • Every reference year falls between 1960 and next year

    Passed

  • Each library's current edition is the one its values come from

    Passed

  • No two editions of a library share a release date

    Passed

  • The parts of a total are never listed twice under one label

    Passed

  • Every residual mix has its green-tariff counterpart

    Passed

  • Every factor points to its top parent

    Passed

  • Every conservative value carries the same label

    Passed

  • Every publisher's quality rating system is read

    Passed

  • Every factor's boundary includes what its category measures

    Passed

  • Every factor uses the most precise boundary for its category

    Passed

  • Every factor is filed under the most specific category its source allows

    Passed · 7,103 in all libraries

  • Every factor has a category

    Passed

  • Every categorised factor has a GHG Protocol scope

    Passed · 39 in all libraries

  • Single-gas values have their AR6 version

    Passed · 10 in all libraries

  • No factor answers a question that does not arise for it

    Passed · 9 in all libraries

  • No part is larger than the total it belongs to

    Passed

  • A supplier named in the source is linked to the factor

    Passed

  • No factor is an unlinked part of another factor

    Passed

  • A part covering the same scope as its total is linked to it

    Passed

  • Every device total that includes its use also gives the manufacturing share (embodied emissions)

    Passed · 115 in all libraries

  • Every estimated vehicle fuel-supply leg matches its sources

    Passed

  • No plug-in vehicle supply-chain estimate is rated above what its method allows

    Passed

  • Every exhaust-only vehicle factor gets a fuel-supply leg or a recorded reason

    Passed

  • A year in a factor's name matches its reference year

    Passed

How the audit works

What can I do with this data?

Open licence · credit the publisher

Your rights

Open licence · keiti-lci-terms
Use it to calculate my own footprint
Yes
Publish my footprint results
Yes, if
  • you credit the publisher
Share the file with my customers
Unclear: ask 한국환경산업기술원 (KEITI)
Put the factors in a product I sell
Unclear: ask 한국환경산업기술원 (KEITI)
Modify it or combine it with my own data
Unclear: ask 한국환경산업기술원 (KEITI)

Publisher's published terms, checked on 10 Nov 2026

ILCD licenseType 'Free of charge for all users and uses' on 280 of the 280 loaded datasets; useRestrictions 'The dataset can be accessed with registration and used freely'

Credit line

Korea National LCI Database, 한국환경산업기술원 (KEITI). Normalised by open-climate.ai, https://open-climate.ai/factors/libraries/keiti_korea/ (CC BY 4.0)

Not legal advice: the publisher's terms prevail.

Full terms

How to read these answers

Coverage

What the library covers, by category and by boundary. Click a slice to drill in, then a sub-category or a boundary to filter the factors below.

By category

Materials: 134Transport: 39Waste treatment: 27Fuels: 25Electricity: 22Water: 14Manufactured goods: 3
264factors

Click a slice to see what is under it. A name opens its category page; its swatch hides it from the ring.

By boundary

Cradle to gate: 176Energy, full chain: 61End of life / waste: 27
264factors

Click a slice to see what is under it. Click a name to hide it from the ring.

Browse factors

top 0 matches

SavedUnfoldFactorRegionBoundary
Unit
VersionPublishedLoadedStatusSource
node-20261109–16 Nov 2026ServedSource

Methodology

How this works
  • Each dataset is a modelled life-cycle inventory result for one Korean product or service, built from industry data and combined with Korean and international background data.
  • The climate value is the dataset's own EF 3.1 climate-change result, as printed, in kg CO2e per unit. EF 3.1 uses the IPCC Sixth Assessment Report values. Biogenic CO2 counts as zero; CO2 from land-use change is counted. The dataset prints the total split into fossil, biogenic and land-use parts, and we keep the split.
  • Boundaries: materials, chemicals and fuels are cradle to gate; electricity and freight transport are the energy carrier's full life cycle; waste and wastewater treatments are end of life.
  • Electricity: the production mix (0.5117 kg CO2e per kWh) is generation only, without network losses; the market mix (0.5304 kg CO2e per kWh) includes transmission and distribution losses.
  • Shipping: 22 freight-ship datasets are published twice, as a restricted production-mix dataset and as a free consumption-mix copy with the same value. We load the free copy.
  • Each value's reference year is the dataset's reference year (2021 to 2023).

Data year: the ILCD reference year of each dataset (2021-2023); the dataset's validity end is kept apart and is never a reference year.

What we import

  • 280 factors and 280 values, all for South Korea.
  • Units: 215 per kg, 39 per tonne-kilometre, 22 per kWh and 4 per cubic metre of wastewater treated.
  • Factors are placed in the open-climate.ai category tree: 132 under materials, 45 under waste, 39 under transport, 25 under fuels, 22 under electricity, 14 under water and 3 under manufactured goods.
  • Names are KEITI's English dataset names, with French and German beside them. Each factor carries the dataset's English description.
  • Not imported: 52 datasets with no climate result, 6 power plants given per piece, 5 datasets with no reference flow, 2 pyrolysis oils under a restricted licence, and the 22 restricted shipping twins (their values load through the free copies). The 160 datasets behind registration are not loaded yet. Of each dataset we keep the climate result only; the other EF 3.1 indicators and the exchange inventory stay out.

Open. Every loaded dataset states the licence type "Free of charge for all users and uses". Using the factors for your own footprint and publishing results that use them are allowed with attribution. The terms do not say explicitly whether the values may be redistributed, embedded in a product or modified, so those uses are not confirmed. Attribution: "Korea National LCI Database, 한국환경산업기술원 (KEITI)." Last verified 2026-11-10.

What can I do with this data?

Credit line: Korea National LCI Database, 한국환경산업기술원 (KEITI)

keiti-lci-terms

Free of charge for all users and uses

Limitations

  • The values are cradle-to-gate or end-of-life results, not combustion factors: do not add a fuel-chain leg to them.
  • 240 of 280 datasets have passed the validity date KEITI set (2024 or 2025). They are the edition the node serves, so we load them.
  • 19 waste-treatment names come as two datasets each with near-equal values; both are loaded.
  • There is no per-gas split (CO2, methane, nitrous oxide), so no value on the Fifth Assessment Report basis.
  • KEITI prints no data-quality rating; 270 of 280 datasets state an external review. The values are rated medium quality.
  • How quality tiers are set.

Changelog

  • 2026-11-10: open set of the KEITI node harvested on 2026-11-09 loaded (280 factors, 280 values).

Know a newer edition?

If KEITI LCI has published an edition we do not serve yet, tell us where to find it.