Ferry travel emission factors
Passenger travel by ferry. From 9 libraries, filed in one model so one publisher's factor compares with another's.
Median 0.27 kgCO₂e/p.km over 10 factors, from 0.023 to 1.42.
Group: Per p.km, Well-to-use
How much CO₂e, at a glance
The median of the largest groups that compare. A group shares one unit, one boundary and one accounting method, so a card never mixes them.
Per p.km
Well-to-use
0.27 kg CO₂e
Median of 10 factors. Half of them sit between 0.143 and 0.709.
Per CAD spent
Cradle to store gate, Purchaser prices
0.701 kg CO₂e
Median of 8 factors. Half of them sit between 0.497 and 0.937.
Source: open-climate.ai catalogue, version 2360, coverage summed over libraries.
How far apart the factors are
One row per comparable group, each chart on its own scale. Physical units and spend never share a chart.
- Lowest to highest
- Middle half of the factors
- Median
Per p.km
| Group | Factors | kg CO₂e per p.km | Lowest | Middle half | Median | Highest |
|---|---|---|---|---|---|---|
| Well-to-use | 10 | 0.023 | 0.143 to 0.709 | 0.27 | 1.42 |
Priced per unit of spend
Spend factors price a unit of currency, not a quantity. They are drawn apart and never ranked with physical factors. Spend or activity: which to use
Per CAD spent · Purchaser prices
| Group | Factors | kg CO₂e per CAD | Lowest | Middle half | Median | Highest |
|---|---|---|---|---|---|---|
| Cradle to store gate, Purchaser prices | 8 | 0.446 | 0.497 to 0.937 | 0.701 | 1.99 |
Source: open-climate.ai catalogue, version 2360, coverage summed over libraries.
One thing, several units
Each unit is its own comparison. A factor per litre never sits on one axis with a factor per kilogram, and a factor per unit of spend never sits with a physical one: convert your quantity into the factor's unit, not the factor.
per p.km
11 factors
Boundaries: Well-to-use (upstream, burn or generation, network losses) and Combustion (direct, at point of use)
per km
3 factors
Boundaries: Well-to-use (upstream, burn or generation, network losses) and Combustion (direct, at point of use)
per visit
1 factor
Boundaries: Energy, full life cycle (fuel cycle and asset)
per unit of spend (CAD)
8 factors
What does each total include?
4 boundaries are in use in this category, and a total on one does not compare with a total on another. Read down a column to see what it counts.
| Part of the total | Well-to-use12 factors | Cradle to store gate8 factors | Combustion2 factors | Energy, full life cycle1 factor |
|---|---|---|---|---|
| Imported inputs | Not stated | Included | Not stated | Not stated |
| Transmission and distribution losses | Not included | Not stated | Not included | Not stated |
| Upstream fuel (well-to-tank) | Included | Included | Not included | Not stated |
| Fuel combustion | Included | Included | Included | Not stated |
| Purchased electricity and heat | Not included | Included | Not included | Not stated |
| Business travel | Not stated | Included | Not stated | Not stated |
| Capital goods | Not included | Included | Not included | Not stated |
| Employee commuting | Not stated | Not included | Not stated | Not stated |
| Infrastructure | Not included | Not stated | Not included | Not stated |
| Overheads and services | Not stated | Included | Not stated | Not stated |
Varies: some factors on this boundary include it and others do not. Not stated: the publisher does not say. How system boundaries work
Which factor should you use?
Who moves what decides the scope. What you know, the distance or the fuel, decides the unit.
Your own vehicles
Trucks, vans or cars you operate. Scope 1.
Use the fuel you bought where you know it, and a per-km factor only when you know the distance and not the fuel.
Freight someone moves for you
Goods carried by a carrier. Scope 3 category 4 or 9.
Use a per tonne-km factor for the same mode, with the weight and the distance carried.
Business travel
Flights, trains and taxis for staff. Scope 3 category 6.
Use a per passenger-km factor for the same mode. For a flight, check whether it counts radiative forcing.
Only a spend figure
You know what you paid, not the quantity.
Use a spend factor in the currency and year of the invoice.
Libraries that publish these factors
9 libraries, by number of factors.
| Library | Factors | Boundary | Values | Latest |
|---|---|---|---|---|
| OpenIO-Canada | 8 | Cradle to store gate | Shown | 2023 |
| ADEME | 4 | Well-to-use | Shown | 2020 |
| DCE | 3 | Well-to-use, Combustion | Shown | 2020 |
| DESNZ | 3 | Well-to-use | Shown | 2026 |
| CO2emissiefactoren.be | 1 | Well-to-use | Shown | 2026 |
| CO2emissiefactoren.nl | 1 | Well-to-use | Shown | 2026 |
| MfE | 1 | Well-to-use | Shown | 2024 |
| MOENV coefficients | 1 | Energy, full life cycle | Shown | 2017 |
1 more library
| OCCC | 1 | Combustion | Shown | 2025 |
Source: open-climate.ai catalogue, version 2360, coverage summed over libraries.
Other subcategories
- Road freight3,886 factors
- Car travel2,500 factors
- Multimodal freight1,425 factors
- Sea freight1,007 factors
- Logistics and warehousing889 factors
- Bus and coach travel806 factors
- Pipeline transport793 factors
- Multimodal passenger travel758 factors
- Air travel507 factors
- Motorcycle and scooter travel441 factors
- Rail freight389 factors
- Air freight326 factors
- Rail travel301 factors
- Inland waterway freight176 factors
Have a procurement file?
Send it and we'll match every line.
Highlighted factor pages
Sorted by library. Each factor is also on its library's page.
| Activity | Library | Region | Boundary | Value | Year |
|---|---|---|---|---|---|
| Ferry - Foot passenger | DESNZ | United Kingdom | Well-to-use | 0.023 kgCO₂e/p.km | 2026 |
| Public Transport Passenger Travel - Ferry - Ferry Average | MfE | New Zealand | Combustion | 0.662 kgCO₂e/p.km | 2024 |
| Water passenger transportation services | OpenIO-Canada | Quebec | Cradle to store gate | 0.9 kgCO₂e/CAD | 2023 |