EXIOBASE

A global multi-regional input-output model that gives the supply chain emissions per euro spent on 200 products in 49 countries and regions.

Research
  • Spend
GeneralistCopyleft licence
Factors
8,064
Values
56,448

One per year and method

Countries
44

49 regions, sub-national included

Edition
3.8.2

published 21 Oct 2021 · all versions

Last loaded
18 Aug 2026

Report a newer version

Overview

EXIOBASE 3 is an environmentally extended multi-regional input-output model. It links the economic transactions between sectors in different countries to the emissions each sector causes, so a purchase can be traced through its whole upstream supply chain. Version 3.8.2 is published on Zenodo.

It is built for spend-based accounting, where only the amount paid for a product is known. It covers 44 countries and 5 rest-of-world regions.

At a glance

Publisher
EXIOBASE
Kind
Research
Scope
Generalist7 categories each hold at least 5% of its factors; the largest, Materials, holds 23.6%. A generalist needs 4.
Home region
World
Edition
3.8.2
Licence
Copyleft licence (cc-by-sa-4.0)

Standardised file

EXIOBASE, standardised by open-climate.ai

The publisher's file, re-cut into the schema every library on open-climate.ai shares: one category axis, coded regions, canonical units, AR6 warming potentials, the source row kept beside each value. What is in the file

  • Edition 3.8.2xlsxen8,064 rows · built 2026-09-01 · 1263a96ac33cfree account required
  • Edition 3.8.2csven8,064 rows · built 2026-09-01 · 3e7be3edd64afree account required

What open-climate.ai standardised

over the publisher's own fileHow we standardise

Warming potentials

None is converted: every value keeps the publisher's GWP.

8,064 factor values left on the publisher's GWP

6 more things standardised

Audit checks

90 passed2 known limitations3 enforced when loadedlast run 25 Sept 2026

Checks we run on every load to keep the data above trustworthy. Counts are for this library; the grey figure is the same check across all libraries. Point at the i to see why a check matters.

What the statuses meanHow checks are countedWhy we checkHow checks are grouped

Needs attention

  • No default value is withheld for poor quality

    Known limitation · 1,736 in this library

  • Translations match the current source text

    Known limitation · 18,277 in this library · 286,941 in all libraries

One category axis

Learn more
  • Every source category maps to our vocabulary

    Enforced when loaded

  • The publisher's classification is kept

    Passed

  • Every classification level has a valid parent

    Passed

  • Every product code comes with the codes above it

    Passed

  • A publisher's own classification is used only by that publisher

    Passed

  • A standard classification code has one label in every library

    Passed

Coded regions

Learn more
  • Every region is a known code

    Enforced when loaded

  • No named region is filed under a broader one

    Passed

  • Every region sits in the world hierarchy

    Passed

Canonical units

Learn more
  • Every unit is a known code

    Enforced when loaded

  • One source unit maps to one unit

    Passed

  • A unit label means the same in every library

    Passed

  • A unit label that names no basis folds one way

    Passed · 1 in all libraries

Declared boundaries

Learn more
  • Every boundary states what it includes

    Passed

  • Boundary scope terms are known codes

    Passed

  • No two factors for the same activity partly overlap in scope

    Passed

  • Separate stages of one activity are linked as parts

    Passed

  • Every part of a factor states its boundary

    Passed

  • Each biofuel follows one convention for biogenic CO2

    Passed · 12 in all libraries

  • No recycling credit is hidden inside a life-cycle total

    Passed

Warming potentials

Learn more
  • Methane and nitrous oxide figures match the stated GWP

    Passed

  • Every convertible value has its AR6 version

    Passed

  • CO2e totals agree with their gases

    Passed · 3,229 in all libraries

  • Fossil-only values list the gases that back the label

    Passed · 19,942 in all libraries

  • Standardised figures keep every gas the publisher lists

    Passed

  • Every value states what its CO2e total includes

    Passed

  • A library with no AR6 version at all has a recorded reason

    Passed

Spend factors

Learn more
  • Spend factors state their price year and basis

    Passed

Data quality

Learn more
  • Quality ratings fall inside their scale

    Passed

  • Every zero value is explained

    Passed

  • No default value is withheld for poor quality

    Known limitation · 1,736 in this library

  • No implausibly high per-kilogram value is rated reliable

    Passed

  • Every quality level gives a recognised reason

    Passed

  • A zero that is only a gap in the source is withheld

    Passed

  • The library is not rated entirely on one fallback quality level

    Passed

Languages

Learn more
  • Every factor has an English name

    Passed

  • Translations match the current source text

    Known limitation · 18,277 in this library · 286,941 in all libraries

  • Every served factor has a name

    Passed

  • Factors are searched on their English name where one exists

    Passed · 7 in all libraries

  • Every language with a main name also has a full name

    Passed

  • Full names are built from their parts in the same language

    Passed

  • Every text is labelled with its real language

    Passed

  • Every description is available for display and translation

    Passed

  • Every usage note is available for display and translation

    Passed

Traceable to the source

Learn more
  • Values traced to one source row agree with each other

    Passed

  • No duplicate factors are served

    Passed · 302 in all libraries

  • No factor value claims two things that cannot both be true

    Passed · 5,836 in all libraries

  • No factor value the publisher has withdrawn is still served

    Passed · 556 in all libraries

Other checks

  • An activity's grouping key names only the activity

    Passed · 6 in all libraries

  • A Creative Commons credit names its licence

    Passed

  • No note of ours appears in the credit or licence notice

    Passed

  • The credit line carries no terms of use

    Passed

  • Every part links to a valid parent

    Passed

  • Every impact assessment method is a recognised code

    Passed

  • Summed totals keep their parts' classification

    Passed

  • Every summed total has a classification when its parts do

    Passed

  • Green-electricity zeros are not rated below market-based peers

    Passed

  • An avoided credit is linked to the burden it belongs to

    Passed

  • Every value is typed as specific, generic or average

    Passed

  • The market-based value is the default

    Passed

  • Summed totals equal their parts on every gas

    Passed

  • Validity dates are the publisher's own, never guessed

    Passed

  • Quality breakdowns use their scheme's axes

    Passed

  • No battery-electric vehicle carries tailpipe emissions

    Passed

  • The text of each estimated factor matches its current figures

    Passed

  • A total built on an estimated part is marked as estimated

    Passed

  • Every estimate is built only from data we may redistribute

    Passed

  • No estimated factor is rated above the data it was built from

    Passed

  • No estimate is served where the publisher printed the figure

    Passed

  • Every estimated factor still matches the inputs it was computed from

    Passed

  • Every factor with a current value has a default

    Passed

  • Every factor has a value, in a library that publishes values

    Passed

  • Every fixed group of regions lists what it covers

    Passed

  • Where both exist, the residual mix is shown before the green-tariff zero

    Passed

  • Every green-electricity zero is a market-based value

    Passed

  • Every electricity factor states its mix

    Passed

  • The newest edition of each value is the one marked current

    Passed

  • Factor descriptions describe the factor, not the whole library

    Passed

  • Every library's licence has its rights recorded

    Passed

  • Every green-electricity zero is exactly zero and says why

    Passed

  • Green-electricity zeros cover power generation only

    Passed

  • Only a total we computed may mix GWP vintages

    Passed

  • One default value per factor and year

    Passed

  • Every value has a number, a GWP version and a reference year

    Passed

  • No factor description is too long to display in full

    Passed · 4 in all libraries

  • Every excused arithmetic disagreement is stated

    Passed

  • Every reference year falls between 1960 and next year

    Passed

  • The parts of a total are never listed twice under one label

    Passed

  • Every residual mix has its green-tariff counterpart

    Passed

  • Every factor points to its top parent

    Passed

  • Every publisher's quality rating system is read

    Passed

  • A supplier named in the source is linked to the factor

    Passed

  • No factor is an unlinked part of another factor

    Passed

  • A part covering the same scope as its total is linked to it

    Passed

  • A year in a factor's name matches its reference year

    Passed

How the audit works

What can I do with this data?

Copyleft licence · credit the publisher

Your rights

Copyleft licence · cc-by-sa-4.0
Use it to calculate my own footprint
Yes
Publish my footprint results
Yes, if
  • you credit the publisher
  • you say what you changed
  • you share the result under the same licence
Share the file with my customers
Yes, if
  • you credit the publisher
  • you say what you changed
  • you share the result under the same licence
Put the factors in a product I sell
Yes, if
  • you credit the publisher
  • you say what you changed
  • you share the result under the same licence
Modify it or combine it with my own data
Yes, if
  • you credit the publisher
  • you say what you changed
  • you share the result under the same licence

Named licence, checked on 17 Jul 2026

CC BY-SA 4.0 grants CC BY's rights; §3(b) adds that Adapted Material You Share carries a BY-SA licence (same elements, this version or later), so the obligation travels with anything blended from it.

Credit line

Data: EXIOBASE 3 (Stadler et al.), CC BY-SA 4.0. Normalised by open-climate.ai, https://open-climate.ai/factors/libraries/exiobase (CC BY-SA 4.0)

Not legal advice: the publisher's terms prevail.

Full termsWhere this answer comes from

How to read these answers

Coverage

What the library covers, by category and by boundary. Click a slice to drill in, then a sub-category or a boundary to filter the factors below.

By category

Materials: 1,903Fuels: 1,439Food and agriculture: 1,200Services: 1,022Waste treatment: 889Manufactured goods: 581Electricity: 551Transport: 341Other (3): 138
8,064factors

Click a slice to see what is under it. Click a name to hide it from the ring.

By boundary

Cradle to gate: 8,064
8,064factors

Click a slice to see what is under it. Click a name to hide it from the ring.

Browse factors

top 0 matches

SavedUnfoldActivitySub-categoryRegionBoundaryUnitGWP

Checked for updates 18 Sept 2026: the publisher has released something newer, which we are reviewing (1 signal watched)

VersionPublishedLoadedStatusSource
3.8.221 Oct 202118 Aug 2026ServedSource

Methodology

How this works
  • Factors are kg CO2e per euro at basic prices, from the 2019 product-by-product table. The model publishes them per million euros; we store them per euro.
  • Each factor is cradle to gate: it covers the product's whole supply chain, purchased services included. Capital goods are not included, because investment is final demand in the model.
  • Every factor carries seven greenhouse gas characterisations. The default is IPCC AR5 with a 100-year horizon. The others use AR4-era factors, 20- and 500-year horizons or other characterisation models, and stay selectable beside it.
  • The total is an economy-wide figure allocated through the model; biogenic CO2 is treated as neutral.
  • Values are adjusted for inflation to each accounting year from 2015 to 2025, with each region's price change carried into euros through annual exchange rates.
  • The reference year is 2019, the year of the table.

Data year: the year of the MRIO table the factor comes from.

What we import

  • EXIOBASE 3.8.2, product-by-product table for 2019: 200 products for 49 countries and regions, 9,800 factors.
  • Products are classified in NACE Rev. 1.1, derived from the EXIOBASE product code.
  • 8,064 factors are served. The other 1,736 are withheld as unreliable: 1,662 structural zeros where the model has no data, and 74 extreme values caused by a very small denominator.
  • Not imported: the industry-by-industry table and the impacts other than greenhouse gases. The emissions by gas are kept in our archive but not served.
  • English names are EXIOBASE's own; French names are machine translated.

Copyleft. EXIOBASE 3.8.2 is published under CC BY-SA 4.0, which allows commercial use and redistribution with attribution.

ShareAlike applies: values derived from or blended with EXIOBASE must be shared under the same licence. Do not mix them into a result you publish under a more permissive licence.

Versions from 3.9.4 onwards carry a non-commercial licence. That is why we stay on 3.8.2.

What can I do with this data?

Credit line: EXIOBASE 3 (Stadler et al.), CC BY-SA 4.0

cc-by-sa-4.0

Limitations

  • A spend-based factor averages a whole product group. A physical or supplier-specific factor is more accurate when available.
  • Factors are at basic prices. A purchase ledger records purchaser prices, which include trade and transport margins and taxes, so applying a basic price factor to it understates emissions.
  • The table year is 2019. Newer editions are not loaded, because of their licence.
  • The characterisations are AR5 and AR4 based and cannot be restated in AR6, because the breakdown by gas is not kept.
  • Capital goods are outside every factor.

Changelog

  • 2026-09-15: every factor states that purchased services are inside it and capital goods outside.
  • 2026-09-10: factors adjusted for inflation per accounting year.
  • 2026-08-18: two products moved to a better category: medical and precision instruments, and equipment rental.
  • 2026-07-30: structural zeros and extreme values withheld from serving.
  • 2026-07-24: EXIOBASE 3.8.2 loaded.

Know a newer edition?